FieldServer Envirotronics SystemsPlus FS 8700 88 User Manual |
A Sierra Monitor Company
Driver Manual
(Supplement to the FieldServer Instruction Manual)
FS-8700-88 Envirotronics SystemsPlus
APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after May 1, 2001
Driver Version:
1.02
Document Revision: 6
FS-8700-88 Envirotronics SystemsPlus
Table of Contents
4.4.39. Map Descriptor Example 36 - stop program .......................................................21
4.4.40. Map Descriptor Example 37 - stop system .........................................................21
4.4.41. Map Descriptor Example 38 - alarm reset...........................................................21
4.4.42. Map Descriptor Example 39 - alarm acknowledge..............................................21
4.4.43. Map Descriptor Example 40 - edit alarms...........................................................22
4.4.44. Map Descriptor Example 41 - set circulators = Boolean .....................................22
4.4.45. Map Descriptor Example 42 - set lights = Boolean .............................................22
4.4.46. Map Descriptor Example 43 - select program program_num..............................22
4.4.47. Map Descriptor Example 44 - use keypad = Boolean.........................................23
4.4.48. Map Descriptor Example 45 - edit program program_num .................................23
4.4.49. Map Descriptor Example 46 - edit step step_num ..............................................23
4.4.50. Map Descriptor Example 47 - edit analog channel..............................................23
4.4.51. Map Descriptor Example 48 - edit fuzzy channel................................................24
4.4.52. Map Descriptor Example 49 - edit remove step..................................................24
4.4.53. Map Descriptor Example 50 - edit insert step .....................................................24
4.4.54. Map Descriptor Example 51 - edit add step........................................................24
4.4.55. Map Descriptor Example 52 - edit clear program................................................25
4.4.56. Map Descriptor Example 53 - use emulator mode..............................................25
4.4.57. Map Descriptor Example 54 - end edit mode......................................................25
4.4.58. Map Descriptor Example 55 - edit set cycles = num_cycles ...............................25
4.4.59. Map Descriptor Example 56 - edit set next = next_step_num.............................26
4.4.60. Map Descriptor Example 57 - edit set analog min. = value.................................26
4.4.61. Map Descriptor Example 58 - edit set analog max. = value................................26
4.4.62. Map Descriptor Example 59 - edit set analog type = number..............................26
4.4.63. Map Descriptor Example 60 - edit set engineering min. = value .........................27
4.4.64. Map Descriptor Example 61 - edit set engineering max. = value ........................27
4.4.65. Map Descriptor Example 62 - edit set analog address = number........................27
4.4.66. Map Descriptor Example 63 - edit set units = number ........................................27
4.4.67. Map Descriptor Example 64 - edit set fuzzy heat cycles time = value.................28
4.4.68. Map Descriptor Example 65 - edit set fuzzy cool cycles time = value .................28
4.4.69. Map Descriptor Example 66 - edit set fuzzy heat sensitivity = value...................28
4.4.70. Map Descriptor Example 67- edit set fuzzy cool sensitivity = value ....................28
4.4.71. Map Descriptor Example 68 - edit set fuzzy heat max. power = value................29
4.4.72. Map Descriptor Example 69 - edit set fuzzy cool max. power = value.................29
4.4.73. Map Descriptor Example 70 - edit set fuzzy heat min. time = value....................29
4.4.74. Map Descriptor Example 71 - edit set fuzzy cool min. time = value ....................29
4.4.75. Map Descriptor Example 72 - edit set fuzzy heat stage delay = value ................30
4.4.76. Map Descriptor Example 73 - edit set fuzzy cool stage delay = value.................30
4.4.77. Map Descriptor Example 74 - edit set fuzzy dead band = value .........................30
4.4.78. Map Descriptor Example 75 - edit set duration = hour:minute:second................31
4.4.79. Map Descriptor Example 76 - set start time = month/day hour:minute................31
4.4.80. Map Descriptor Example 77 - set stop time = month/day hour:minute................32
4.4.81. Map Descriptor Example 78 - set date = month / day / year ...............................32
4.4.82. Map Descriptor Example 79 - set time = hour:minute:second.............................33
4.4.83. Map Descriptor Example 80 - edit set setpoint channel = value..........................33
4.4.84. Map Descriptor Example 80 - edit set gsoak channel = value.............................34
4.4.85. Map Descriptor Example 81 - edit set gsoak enabled channel = Boolean...........34
4.4.86. Map Descriptor Example 82 - edit set events = event_list...................................35
4.4.87. Map Descriptor Example 83 - edit set auxs = aux_list ........................................35
4.4.88. Map Descriptor Example 84 - edit read program ................................................36
4.4.89. Map Descriptor Example 85 - edit read step.......................................................36
FS-8700-88 Envirotronics SystemsPlus
Table of Contents
4.4.90. Map Descriptor Example 86 - edit read number steps........................................36
4.4.91. Map Descriptor Example 87 - edit read duration.................................................37
4.4.92. Map Descriptor Example 88 - edit read events...................................................37
4.4.93. Map Descriptor Example 89 - edit read aux........................................................38
4.4.94. Map Descriptor Example 90 - edit read cycles....................................................38
4.4.95. Map Descriptor Example 91 - edit read next.......................................................39
4.4.96. Map Descriptor Example 92 - edit read analog min. ...........................................39
4.4.97. Map Descriptor Example 93 - edit read analog max. ..........................................39
4.4.98. Map Descriptor Example 94 - edit read analog type ...........................................40
4.4.99. Map Descriptor Example 95 - edit read engineering min. ...................................40
4.4.100.
4.4.101.
4.4.102.
4.4.103.
4.4.104.
4.4.105.
4.4.106.
4.4.107.
4.4.108.
4.4.109.
4.4.110.
4.4.111.
4.4.112.
4.4.113.
4.4.114.
4.4.115.
4.4.116.
4.4.117.
4.4.118.
4.4.119.
Map Descriptor Example 96 - edit read engineering max. ...............................40
Map Descriptor Example 97 - edit read analog address..................................41
Map Descriptor Example 98 - edit read units...................................................41
Map Descriptor Example 99 - edit read fuzzy heat cycle time..........................41
Map Descriptor Example 100 - edit read fuzzy cool cycle time........................42
Map Descriptor Example 101 - edit read fuzzy heat sensitivity........................42
Map Descriptor Example 102 - edit read fuzzy cool sensitivity ........................42
Map Descriptor Example 103 - edit read fuzzy heat max. power.....................43
Map Descriptor Example 104 - edit read fuzzy cool max. power .....................43
Map Descriptor Example 105 - edit read fuzzy heat min. time.........................43
Map Descriptor Example 106 - edit read fuzzy cool min. time .........................44
Map Descriptor Example 107 - edit read fuzzy heat stage delay .....................44
Map Descriptor Example 108 - edit read fuzzy cool stage delay......................44
Map Descriptor Example 109 - edit read fuzzy dead band ..............................45
Map Descriptor Example 110 - read alarm log ................................................45
Map Descriptor Example 111 - edit read setpoint channel...............................45
Map Descriptor Example 112 - edit read gsoak enabled channel....................46
Map Descriptor Example 113 - edit read gsoak channel..................................46
Map Descriptor Example 114 - edit read scan alarm.......................................46
Map Descriptor Example 115 - edit set scan alarm = Boolean.........................47
APPENDIX A. PARAMETER TABLES .................................................................................48
Appendix A.1. System plus data types................................................................................48
Appendix A.2. Legal System PlusCommands.....................................................................48
FS-8700-88 Envirotronics SystemsPlus
Page 5 of 49
1.
Envirotronics SystemsPlus Description
The Envirotronics SystemsPlus driver allows the FieldServer to transfer data to and from
devices over RS-232 using Envirotronics SystemsPlus protocol. The FieldServer can only
emulate a Client.
Max Nodes Supported
FieldServer Mode
Nodes
Comments
Client
1
Only 1 Client node per port allowed
The Envirotronics SystemsPlus driver allows for direct interfacing to a SystemsPlus
Programmer/Controller device. The driver acts as a Client to the device and can be used to
read and set system parameters for status monitoring and control purposes. Combined with
other protocol drivers on a FieldServer such as BACNet, complete SystemsPlus monitoring and
control is made possible via control systems such as Scada.
The driver is not available as a Server since a FieldServer cannot fully emulate a SystemsPlus
device’s interfaces. Any existing Server drivers are for FieldServer testing purposes only.
FS-8700-88 Envirotronics SystemsPlus
Page 6 of 49
2.
Driver Scope of Supply
2.1. Supplied by FieldServer Technologies for this driver
FieldServer Technologies
PART #
Description
FS-8915-10
FS-8917-02
FS-8917-01
FS-8700-88
UTP cable (7 foot) for RS-232 use
RJ45 to DB9F connector adapter
RJ45 to DB25M connection adapter
Driver Manual.
FS-8700-88 Envirotronics SystemsPlus
Page 7 of 49
3.
Hardware Connections
The FieldServer is connected to the SystemsPlus Controller as shown below.
Configure the SystemsPlus Controller according to manufacturer’s instructions.
8917-01 W IRE LIST
DB25M
FUNCTION FROM
TO
COLOUR
RX
CTS
DSR
GND
GND
DTR
RTS
TX
RJ45-01 DB25M-03 W HITE
RJ45-02 DB25M-05 BROW N
RJ45-03
YELLOW
RJ45-04 DB25M-07 GREEN
RJ45-05
RJ45-06
RED
BLACK
RJ45-07 DB25M-04 ORANGE
RJ45-08 DB25M-02
BLUE
8917-02 W IRE LIST
DB9F
FUNCTION FROM
TO
COLOUR
W HITE
Rx
GND
Tx
RJ45-01 DB9F-03
RJ45-04 DB9F-05 GREEN
RJ45-08 DB9F-02
BLUE
Envirotronics SystemsPlus
Controller
RJ45 Connector
OR
(408)-262-2299
FIELDSERVER
ENVIROTRONICS
CONNECTION DIAGRAM
BASE NAME:
FILE NAME:
DATE: 8/30/05
BY: MC
Note:
•
The SystemsPlus Controller MUST be set to COMMAND MODE using the manufacturer’s
software before connecting the FieldServer.
•
The SystemsPlus Controller’s “Command End of Line” setting MUST be set to “CR”. Using
the manufacturer’s software to do this setting before connecting the FieldServer
FS-8700-88 Envirotronics SystemsPlus
Page 8 of 49
4.
Configuring the FieldServer as a Envirotronics SystemsPlus Client
For a detailed discussion on FieldServer configuration, please refer to the FieldServer
instruction manual. The information that follows describes how to expand upon the factory
defaults provided in the configuration files included with the FieldServer (See “.csv” sample files
provided with the FieldServer).
This section documents and describes the parameters necessary for configuring the FieldServer
to communicate with an Envirotronics SystemsPlus Server.
4.1.
Data Arrays/Descriptors
The configuration file tells the FieldServer about its interfaces, and the routing of data
required. In order to enable the FieldServer for Envirotronics SystemsPlus communications,
the driver independent FieldServer buffers need to be declared in the “Data Arrays” section,
the destination device addresses need to be declared in the “Client Side Nodes” section,
and the data required from the Servers needs to be mapped in the “Client Side Map
Descriptors” section. Details on how to do this can be found below.
Note that in the tables, * indicates an optional parameter, with the bold legal value being the
default.
Section Title
Data_Arrays
Column Title
Function
Legal Values
Up to 15 alphanumeric
characters
Data_Array_Name Provide name for Data Array
Float, Bit, UInt16, SInt16,
Packed_Bit, Byte,
Packed_Byte,
Provide data format. Each Data Array
Data_Array_Format
can only take on one format.
Swapped_Byte
Number of Data Objects. Must be
larger than the data storage area
required by the Map Descriptors for the
Data_Array_Length
1-10,000
data being placed in this array.
Example
// Data Arrays
Data_Arrays
Data_Array_Name,
Event_States,
Data_Format,
bit,
Data_Array_Length
10
FS-8700-88 Envirotronics SystemsPlus
Page 9 of 49
4.2.
Client Side Connection Descriptions
Section Title
Connections
Column Title
Function
Specify which port the device is connected
to the FieldServer
Legal Values
Port
P1-P81
Protocol
Baud*
Specify protocol used
SystemsPlus
300 – 19200, standard baud
rates only
Specify baud rate
Even, Odd, None
7, 8
1, 2
Parity*
Data_Bits*
Stop_Bits*
Specify parity
Specify data bits
Specify stop bits
RTS, RTS/CTS, None
0-32000 seconds, 1 second
Handshaking* Specify hardware handshaking
Poll _Delay*
Time between internal polls
Example
// Client Side Connections
Connections
Port,
P1,
Protocol,
SystemsPlus,
Baud,
19200,
Parity,
None,
Handshaking,
None,
Poll_Delay
0.100s
4.3.
Client Side Node Descriptors
Section Title
Nodes
Column Title
Node_Name
Protocol
Function
Provide name for node
Legal Values
Up to 32 alphanumeric
characters
Specify protocol used
SystemsPlus
Specify which port the device is
connected to the FieldServer
Port
P1-P81
Example
// Client Side Nodes
Nodes
Node_Name,
SYSPLUS_01,
Protocol,
SystemsPlus,
Port
P1
1 Not all ports shown are necessarily supported by the hardware. Consult the appropriate Instruction
manual for details of the ports available on specific hardware.
FS-8700-88 Envirotronics SystemsPlus
Page 10 of 49
4.4.
4.4.1.
Client Side Map Descriptors
FieldServer Related Map Descriptor Parameters
Column Title
Function
Name of this Map
Descriptor
Legal Values
Up to 32 alphanumeric
characters
Map_Descriptor_Name
Name of Data Array where
data is to be stored in the
FieldServer
One of the Data Array names
from “Data Array” section
above
Data_Array_Name
Starting location in Data
Array
Function of Client Map
Descriptor
0 to maximum specified in
“Data Array” section above
RDBC, WRBC, WRBX, AWT,
ART2
Data_Array_Offset
Function
4.4.2.
Driver Related Map Descriptor Parameters
Column Title
Function
Legal Values
One of the node names
specified in “Client Node
Descriptor” above
Name of Node to fetch data
from
Node_Name
Specifies a SystemsPlus data
type this mapdesc will use
SysPlus_Data_Type
Refer to Appendix A.1
Any four character alarm
name
SysPlus_Alarm_Name
A SystemsPlus alarm name
Specifies a SystemsPlus
command this mapdesc will
use
SysPlus_Cmd
Refer to Appendix A.2
Name of the data array where
data must be stored
Store_Data_Array_Name
Store_Data_Array_Offset
Any data array name
Offset where data must be
stored
0 to maximum offset into
store data array
Name of the data array that
will contain parameters
needed by this mapdesc
Par_Data_Array_Name
Par_Data_Array_Offset
Any data array name
Offset where parameters will
be located
0 to maximum offset into
parameter data array
0 to value allowed for the
specific mapdesc
1 to value allowed for the
specific mapdesc
Address
Length
Starting address
Length of Map Descriptor
4.4.3.
Timing Parameters
Column Title
Scan_Interval
Function
Legal Values
Rate at which data is polled ≥0.001s
2 The new ART function stands for “Active Read on Trigger” and is used to effect a single data
read per trigger. Please refer to the Map Descriptor examples for using this function.
FS-8700-88 Envirotronics SystemsPlus
Page 11 of 49
4.4.4.
Map Descriptor Example 1 - read event event_num
// Client Side Map Descriptors
Map Descriptors
Map_Descriptor_Name, Scan_Interval, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Data_Type, Address, Length
Event_States_00, 0s, Event_States, 0, rdbc, SYSPLUS_01, Event,
0,
1
The event_num is specified by the “Address” field. The state of the event will be stored as 1 for “ON” or 0 for “OFF”.
4.4.5. Map Descriptor Example 2 - set event event_num = Boolean
// Client Side Map Descriptors
Map Descriptors
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Data_Type, Address, Length
Event_States_00,
Event_States_0,
0,
awt,
SYSPLUS_01, Event,
0,
1
The event_num is specified by the “Address” field. The Boolean state of the event is retrieved from the value written into
Data_Array_Name at Data_Array_Offset. Use a value of 1 for “ON” and a value of 0 for “OFF”.
4.4.6.
Map Descriptor Example 3 - read aux. aux_num
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name, Scan_Interval, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Data_Type, Address, Length
0,
Aux_States_00,
0s,
Aux_States,
0,
rdbc,
SYSPLUS_01, Aux,
1
The aux_num is specified by the “Address” field. The state of the aux will be stored as 1 for “ON” or 0 for “OFF”.
4.4.7. Map Descriptor Example 4 - set aux. aux_num = Boolean
// Client Side Map Descriptors
Map Descriptors
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Data_Type, Address, Length
0,
Aux_States_00,
Aux_States_0,
0,
awt,
SYSPLUS_01, Aux,
1
The aux_num is specified by the “Address” field. The Boolean state of the aux is retrieved from the value written into
Data_Array_Name at Data_Array_Offset. Use a value of 1 for “ON” and a value of 0 for “OFF”.
FS-8700-88 Envirotronics SystemsPlus
Page 12 of 49
4.4.8.
Map Descriptor Example 5 - read setpoint channel
// Client Side Map Descriptors
Map Descriptors
Map_Descriptor_Name, Scan_Interval, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
Setpoints_00, 0s, Setpoints, 0, rdbc, SYSPLUS_01, Setpoint,
SysPlus_Data_Type, Address, Length
0,
1
The channel is specified by the “Address” field.
4.4.9. Map Descriptor Example 6 - set setpoint channel = value
// Client Side Map Descriptors
Map Descriptors
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Data_Type, Address, Length
0,
Setpoints_00,
Setpoints_0,
0,
awt,
SYSPLUS_01, Setpoint,
1
The channel is specified by the “Address” field.
value is retrieved from the value written into Data_Array_Name at
Data_Array_Offset.
4.4.10.
Map Descriptor Example 7 - read pv channel
// Client Side Map Descriptors
Map Descriptors
Map_Descriptor_Name, Scan_Interval, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
Pvs_00, 0s, Pvs, 0, rdbc, SYSPLUS_01, Pv,
SysPlus_Data_Type, Address, Length
0,
1
The channel is specified by the “Address” field.
4.4.11. Map Descriptor Example 8 - read deviation channel
// Client Side Map Descriptors
Map Descriptors
Map_Descriptor_Name, Scan_Interval, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Data_Type, Address, Length
0,
Deviation_00,
0s,
Deviations,
0,
rdbc,
SYSPLUS_01, Deviation,
1
The channel is specified by the “Address” field.
FS-8700-88 Envirotronics SystemsPlus
Page 13 of 49
4.4.12.
Map Descriptor Example 9 - read initial setpoint channel
// Client Side Map Descriptors
Map Descriptors
Map_Descriptor_Name, Scan_Interval, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
Init_Setpoint_00, 0s, Init_Setpoint, 0, rdbc, SYSPLUS_01, Init_Setpoint,
SysPlus_Data_Type, Address, Length
0,
1
The channel is specified by the “Address” field.
4.4.13. Map Descriptor Example 10 - set initial setpoint channel = value
// Client Side Map Descriptors
Map Descriptors
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Data_Type, Address, Length
0,
Init_Setpoint_00,
Init_Setpoint_0,
0,
awt,
SYSPLUS_01, Init_Setpoint,
1
The channel is specified by the “Address” field; value is retrieved from the value written into Data_Array_Name at Data_Array_Offset.
4.4.14. Map Descriptor Example 11 - read program status
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name, Scan_Interval, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Data_Type, Length
Prg_Sts,
0s,
Prog_Status,
0,
rdbc,
SYSPLUS_01, Prog_Status,
1
The program status will be stored to Data_Array_Name at Data_Array_Offset with one of the following possible values:
Program Status VALUE
0
1
2
3
4
5
6
Undefined
Timed Start
Alarm Hold
Hold
Run
Timed Stop
Stop
FS-8700-88 Envirotronics SystemsPlus
Page 14 of 49
4.4.15.
Map Descriptor Example 12 - read remaining step cycles
// Client Side Map Descriptors
// Map Descriptors
Map_Descriptor_Name, Scan_Interval, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Data_Type, Length
Rm_Stp_Cy, 0s, Rem_Stepcycles, 0, rdbc, SYSPLUS_01, Rem_Step_Cyc,
1
4.4.16.
Map Descriptor Example 13 - read selected program
// Client Side Map Descriptors
Map Descriptors
Map_Descriptor_Name,
Sel_Prog,
Scan_Interval,
0s,
Data_Array_Name,
Selected_Prog,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Selected_Prog,
Length
1
4.4.17.
Map Descriptor Example 14 - read step number
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Step_Number,
Scan_Interval,
0s,
Data_Array_Name,
Step_Number,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Step_Number,
Length
1
4.4.18.
Map Descriptor Example 15 - read step time
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Step_Time,
Scan_Interval,
0s,
Data_Array_Name,
Step_Time,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Step_Time,
Length
3
The retrieved step time will be stored as follows in Data_Array_Name:
Offset from Data_Array_Offset Description
0
1
2
Hour
Minute
Second
FS-8700-88 Envirotronics SystemsPlus
Page 15 of 49
4.4.19.
Map Descriptor Example 16 - read remaining step time
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Rm_Stp_Tm,
Scan_Interval,
0s,
Data_Array_Name,
Rem_Steptime,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Rem_Step_Tim,
Length
3
The retrieved remaining step time will be stored as follows in Data_Array_Name:
Offset from Data_Array_Offset Description
0
1
2
Hour
Minute
Second
4.4.20.
Map Descriptor Example 17 -read start step
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Start_Step,
Scan_Interval,
0s,
Data_Array_Name,
Start_Step,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Start_Step,
Length
1
4.4.21.
Map Descriptor Example 18 - set start step = step_num
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Start_Step,
Data_Array_Name,
Start_Step_0,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Start_Step,
Length
1
The step_num must be written into Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.22. Map Descriptor Example 19 - read start time enabled
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Start_Time_Ena,
Scan_Interval,
0s,
Data_Array_Name,
Start_Time_Ena,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Start_Time_Ena,
Length
1
The start time enabled status will be stored as 1 for “Enabled” or 0 for “Disabled” in Data_Array_Name at Data_Array_Offset.
FS-8700-88 Envirotronics SystemsPlus
Page 16 of 49
4.4.23.
Map Descriptor Example 20 - set start time enabled = Boolean
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Start_Time_Ena,
Data_Array_Name,
Start_Time_Ena_0,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Start_Time_Ena,
Length
1
A Boolean value of 1 for “Enabled” or 0 for “Disabled” must be written to Data_Array_Name at Data_Array_Offset to trigger this
command.
4.4.24.
Map Descriptor Example 21 - read stop time enabled
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Stop_Time_Ena,
Scan_Interval,
0s,
Data_Array_Name,
Stop_Time_Ena,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Stop_Time_Ena,
Length
1
The stop time enabled status will be stored as 1 for “Enabled” or 0 for “Disabled” in Data_Array_Name at Data_Array_Offset.
4.4.25. Map Descriptor Example 22 - set stop time enabled = Boolean
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Stop_Time_Ena,
Data_Array_Name,
Stop_Time_Ena_0,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Stop_Time_Ena,
Length
1
A Boolean value of 1 for “Enabled” or 0 for “Disabled” must be written to Data_Array_Name at Data_Array_Offset to trigger this
command.
FS-8700-88 Envirotronics SystemsPlus
Page 17 of 49
4.4.26.
Map Descriptor Example 23 - read start time
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Start_Time,
Scan_Interval,
0s,
Data_Array_Name,
Start_Time,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Start_Time,
Length
4
The retrieved start time will be stored as follows in Data_Array_Name:
Offset from Data_Array_Offset Description
0
1
2
3
Month
Day
Hour
Minute
4.4.27.
Map Descriptor Example 24 - read stop time
// Client Side Map Descriptor
Map Descriptor
Map_Descriptor_Name,
Stop_Time,
Scan_Interval,
0s,
Data_Array_Name,
Stop_Time,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Stop_Time,
Length
4
The retrieved stop time will be stored as follows in Data_Array_Name:
Offset from Data_Array_Offset Description
Month
Day
Hour
0
1
2
3
Minute
4.4.28.
Map Descriptor Example 25 - read audible alarm
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Audible_Alarm,
Scan_Interval,
0s,
Data_Array_Name,
Audible_Alarm,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Audible_Alarm,
Length
1
The status of the audible alarm will be stored as 1 for “on” or 0 for “off” in Data_Array_Name at Data_Array_Offset.
FS-8700-88 Envirotronics SystemsPlus
Page 18 of 49
4.4.29.
Map Descriptor Example 26 - set audible alarm = Boolean
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Audible_Alarm,
Data_Array_Name,
Audible_Alarm_0,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Audible_Alarm,
Length
1
A Boolean value of 1 for “on” or 0 for “off” must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.30. Map descriptor Example 27 - read software version
// Cleint Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Sw_Version,
Scan_Interval,
0s,
Data_Array_Name,
Sw_Version,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Sw_Version,
Length
1
4.4.31.
Map Descriptor Example 28 - read events
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
All_Event_States,
Scan_Interval,
0s,
Data_Array_Name,
All_Event_States,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
All_Events,
Length
10
The retrieved event states will be stored as follows in Data_Array_Name:
( A value of 1 will be stored for “on” or 0 for “off” )
Offset from Data_Array_Offset Description
0
1
2
..
9
Event_0 state
Event_1 state
Event_2 state
..
Event_9 state
FS-8700-88 Envirotronics SystemsPlus
Page 19 of 49
4.4.32.
Map Descriptor Example 29 - read auxs
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
All_Aux_States,
Scan_Interval,
0s,
Data_Array_Name,
All_Aux_States,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
All_Auxs,
Length
10
The retrieved aux states will be stored as follows in Data_Array_Name: (A value of 1 will be stored for “on” or 0 for “off”)
Offset from Data_Array_Offset Description
0
1
2
..
9
Aux_0 state
Aux_1 state
Aux_2 state
..
Aux_9 state
4.4.33.
Map Descriptor Example 30 - read alarm status alarm
// Client Side Map Descriptors
Map Descriptor
Map_Descriptor_Name,
Alarm_Sts_00,
Scan_Interval,
0s,
Data_Array_Name,
Alarm_Statuses,
Data_Array_Offset,
0,
Function,
rdbc,
Node_Name,
SYSPLUS_01,
SysPlus_Data_Type,
Alarm,
SysPlus_Alarm_Name,
volt,
Length
1
alarm is specified by the name under SysPlus_Alarm_Name. The status of the alarm will be stored as 1 for “OK” or 0 for “FAIL” in
Data_Array_Name at Data_Array_Offset.
4.4.34.
Map Descriptor Example 31 - emergency stop
// Client Side Map Descriptors
Map Descriptors
Map_Descriptor_Name,
Emergency_Stop,
Data_Array_Name,
ProgSysControl,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Emergency_Stop,
Length
1
Triggger this command by writing any value to Data_Array_Name at Data_Array_Offset.
FS-8700-88 Envirotronics SystemsPlus
Page 20 of 49
4.4.35.
Map Descriptor Example 32 - hold program
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Hold_Program,
Data_Array_Name,
ProgSysControl,
Data_Array_Offset,
1,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Hold_Program,
Length
1
Triggger this command by writing any value to Data_Array_Name at Data_Array_Offset.
4.4.36. Map Descriptor Example 33 - resume program
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Resume_Program,
Data_Array_Name,
ProgSysControl,
Data_Array_Offset,
2,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Resume_Program,
Length
1
Triggger this command by writing any value to Data_Array_Name at Data_Array_Offset.
4.4.37. Map Descriptor Example 34 - start program
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Start_Program,
Data_Array_Name,
ProgSysControl,
Data_Array_Offset,
3,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Start_Program,
Length
1
Triggger this command by writing any value to Data_Array_Name at Data_Array_Offset.
4.4.38. Map Descriptor Example 35 - start system
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Start_System,
Data_Array_Name,
ProgSysControl,
Data_Array_Offset,
4,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Start_System,
Length
1
Triggger this command by writing any value to Data_Array_Name at Data_Array_Offset.
FS-8700-88 Envirotronics SystemsPlus
Page 21 of 49
4.4.39.
Map Descriptor Example 36 - stop program
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Stop_Program,
Data_Array_Name,
ProgSysControl,
Data_Array_Offset,
5,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Stop_Program,
Length
1
Triggger this command by writing any value to Data_Array_Name at Data_Array_Offset.
4.4.40. Map Descriptor Example 37 - stop system
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Stop_System,
Data_Array_Name,
ProgSysControl,
Data_Array_Offset,
6,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Stop_System,
Length
1
Triggger this command by writing any value to Data_Array_Name at Data_Array_Offset.
4.4.41. Map Descriptor Example 38 - alarm reset
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Alarm_Reset,
Data_Array_Name,
AlarmControl,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Alarm_Reset,
Length
1
Triggger this command by writing any value to Data_Array_Name at Data_Array_Offset.
4.4.42. Map Descriptor Example 39 - alarm acknowledge
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Alarm_Ack,
Data_Array_Name,
AlarmControl,
Data_Array_Offset,
1,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Alarm_Ack,
Length
1
Triggger this command by writing any value to Data_Array_Name at Data_Array_Offset.
FS-8700-88 Envirotronics SystemsPlus
Page 22 of 49
4.4.43.
Map Descriptor Example 40 - edit alarms
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Edit_Alarms,
Data_Array_Name,
Edit_Alarms,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Alarms,
Length
1
Triggger this command by writing any value to Data_Array_Name at Data_Array_Offset.
4.4.44. Map Descriptor Example 41 - set circulators = Boolean
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Set_Circs,
Data_Array_Name,
ManualControl,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Set_Circs,
Length
1
Write a value of 1 for “on” or 0 for “off” to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.45. Map Descriptor Example 42 - set lights = Boolean
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Set_Lights,
Data_Array_Name,
ManualControl,
Data_Array_Offset,
1,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Set_Lights,
Length
1
Write a value of 1 for “on” or 0 for “off” to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.46. Map Descriptor Example 43 - select program program_num
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Select_Program,
Data_Array_Name,
Program_Num,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Select_Prog,
Length
1
A program_num value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
FS-8700-88 Envirotronics SystemsPlus
Page 23 of 49
4.4.47.
Map Descriptor Example 44 - use keypad = Boolean
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Use_Keypad,
Data_Array_Name,
Use_Keypad,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Use_Keypad,
Length
1
A Boolean value of 1 for “true” or 0 for “false” must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.48. Map Descriptor Example 45 - edit program program_num
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Program,
Data_Array_Name,
Ed_Program,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Program,
Length
1
A program_num value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.49. Map Descriptor Example 46 - edit step step_num
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Step,
Data_Array_Name,
Ed_Step,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Step,
Length
1
A step_num value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.50. Map Descriptor Example 47 - edit analog channel
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Analog,
Data_Array_Name,
Ed_Analog,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Analog,
Length
1
A channel value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
FS-8700-88 Envirotronics SystemsPlus
Page 24 of 49
4.4.51.
Map Descriptor Example 48 - edit fuzzy channel
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Fuzzy,
Data_Array_Name,
Ed_Fuzzy,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Fuzzy,
Length
1
A channel value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.52. Map Descriptor Example 49 - edit remove step
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Remove_Step,
Data_Array_Name,
Ed_Remove_Step,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Remove_Step,
Length
1
Any value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.53.
Map Descriptor Example 50 - edit insert step
Map_Descriptor_Name,
Ed_Insert_Step,
Data_Array_Name,
Ed_Insert_Step,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Insert_Step,
Length
1
Any value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.54. Map Descriptor Example 51 - edit add step
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Add_Step,
Data_Array_Name,
Ed_Add_Step,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Add_Step,
Length
1
Any value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
FS-8700-88 Envirotronics SystemsPlus
Page 25 of 49
4.4.55.
Map Descriptor Example 52 - edit clear program
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Clr_Program,
Data_Array_Name,
Ed_Clr_Program,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Clr_Program,
Length
1
Any value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.56. Map Descriptor Example 53 - use emulator mode
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Use_Emu_Mode,
Data_Array_Name,
Misc_Cmds,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Use_Emu_Mode,
Length
1
A value of 1 to use emulator mode or a value of 0 to return to command mode must be written to Data_Array_Name at
Data_Array_Offset to trigger this command. Note that all driver RDBC function Map Descriptors are stopped when entering emulator
mode. Map Descriptors will resume polling when returning to command mode.
4.4.57.
Map Descriptor Example 54 - end edit mode
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
End_Edit_Mode,
Data_Array_Name,
Misc_Cmds,
Data_Array_Offset,
1,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
End_Edit_Mode,
Length
1
Any value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.58. Map Descriptor Example 55 - edit set cycles = num_cycles
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Cycles,
Data_Array_Name,
Ed_Cycles,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Cycles,
Length
1
A value of num_cycles must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
FS-8700-88 Envirotronics SystemsPlus
Page 26 of 49
4.4.59.
Map Descriptor Example 56 - edit set next = next_step_num
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Next,
Data_Array_Name,
Ed_Next,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Next,
Length
1
A value of next_step_num must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.60. Map Descriptor Example 57 - edit set analog min. = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Ana_Min,
Data_Array_Name,
Ed_Set_Ana_Min,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Ana_Min,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.61. Map Descriptor Example 58 - edit set analog max. = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Ana_Max,
Data_Array_Name,
Ed_Set_Ana_Max,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Ana_Max,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.62. Map Descriptor Example 59 - edit set analog type = number
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Ana_Type,
Data_Array_Name,
Ed_Set_Ana_Type,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Ana_Type,
Length
1
A value of number must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
FS-8700-88 Envirotronics SystemsPlus
Page 27 of 49
4.4.63.
Map Descriptor Example 60 - edit set engineering min. = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Eng_Min,
Data_Array_Name,
Ed_Set_Eng_Min,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Eng_Min,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.64. Map Descriptor Example 61 - edit set engineering max. = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Eng_Max,
Data_Array_Name,
Ed_Set_Eng_Max,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Eng_Max,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.65. Map Descriptor Example 62 - edit set analog address = number
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Ana_Addr,
Data_Array_Name,
Ed_Set_Ana_Addr,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Ana_Addr,
Length
1
A value of number must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.66. Map Descriptor Example 63 - edit set units = number
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Units,
Data_Array_Name,
Ed_Set_Units,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Units,
Length
1
A value of number must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
FS-8700-88 Envirotronics SystemsPlus
Page 28 of 49
4.4.67.
Map Descriptor Example 64 - edit set fuzzy heat cycles time = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Fuz_Hct,
Data_Array_Name,
Ed_Set_Fuz_Hct,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Fuz_Hct,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.68. Map Descriptor Example 65 - edit set fuzzy cool cycles time = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Fuz_Cct,
Data_Array_Name,
Ed_Set_Fuz_Cct,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Fuz_Cct,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.69. Map Descriptor Example 66 - edit set fuzzy heat sensitivity = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Fuz_HSens,
Data_Array_Name,
Ed_Set_Fuz_HSens,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Fuz_HSens,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.70. Map Descriptor Example 67- edit set fuzzy cool sensitivity = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Fuz_CSens,
Data_Array_Name,
Ed_Set_Fuz_CSens,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Fuz_CSens,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
FS-8700-88 Envirotronics SystemsPlus
Page 29 of 49
4.4.71.
Map Descriptor Example 68 - edit set fuzzy heat max. power = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Fuz_HMPwr,
Data_Array_Name,
Ed_Set_Fuz_HMPwr,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Fuz_HMPwr,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.72. Map Descriptor Example 69 - edit set fuzzy cool max. power = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Fuz_CMPwr,
Data_Array_Name,
Ed_Set_Fuz_CMPwr,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Fuz_CMPwr,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.73. Map Descriptor Example 70 - edit set fuzzy heat min. time = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Fuz_HMTim,
Data_Array_Name,
Ed_Set_Fuz_HMTim,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Fuz_HMTim,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.74. Map Descriptor Example 71 - edit set fuzzy cool min. time = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Fuz_CMTim,
Data_Array_Name,
Ed_Set_Fuz_CMTim,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Fuz_CMTim,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
FS-8700-88 Envirotronics SystemsPlus
Page 30 of 49
4.4.75.
Map Descriptor Example 72 - edit set fuzzy heat stage delay = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Fuz_HSDly,
Data_Array_Name,
Ed_Set_Fuz_HSDly,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Fuz_HSDly,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.76. Map Descriptor Example 73 - edit set fuzzy cool stage delay = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Fuz_CSDly,
Data_Array_Name,
Ed_Set_Fuz_CSDly,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Fuz_CSDly,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.77. Map Descriptor Example 74 - edit set fuzzy dead band = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Fuz_Deadb,
Data_Array_Name,
Ed_Set_Fuz_Deadb,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Fuz_Deadb,
Length
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
FS-8700-88 Envirotronics SystemsPlus
Page 31 of 49
4.4.78.
// Client Side Mao Descriptors
Map Descriptor
Map Descriptor Example 75 - edit set duration = hour:minute:second
Map_Descriptor_Name,
Ed_Set_Duration,
Data_Array_Name,
Par_Bit_Triggers,
Data_Array_Offset,
0,
Function,
awt,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Duration,
Par_Data_Array_Name,
Ed_Set_Duration,
Par_Data_Array_Offset,
0,
Length
1
This command is used by first writing the parameter data (hour:minute:second) and then triggering the command by writing any value
to Data_Array_Name at Data_Array_Offset.
Parameter data setup:
Offset from par_data_array_offset Description
Hour
Minute
Second
0
1
2
4.4.79.
Map Descriptor Example 76 - set start time = month/day hour:minute
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
Set_Start_Time, Par_Bit_Triggers, 1, awt, SYSPLUS_01, Set_Start_Time, Set_Start_Time,
SysPlus_Cmd,
Par_Data_Array_Name, Par_Data_Array_Offset, Length
0,
1
This command is used by first writing the parameter data and then triggering the command by writing any value to Data_Array_Name
at Data_Array_Offset.
Parameter data setup:
Offset from par_data_array_offset Description
Month
Day
Hour
0
1
2
3
Minute
FS-8700-88 Envirotronics SystemsPlus
Page 32 of 49
4.4.80.
Map Descriptor Example 77 - set stop time = month/day hour:minute
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Par_Data_Array_Name, Par_Data_Array_Offset, Length
0,
Set_Stop_Time,
Par_Bit_Triggers,
2,
awt,
SYSPLUS_01, Set_Stop_Time, Set_Stop_Time,
1
This command is used by first writing the parameter data and then triggering the command by writing any value to Data_Array_Name
at Data_Array_Offset.
Parameter data setup:
Offset from par_data_array_offset Description
Month
Day
Hour
0
1
2
3
Minute
4.4.81.
Map Descriptor Example 78 - set date = month / day / year
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd, Par_Data_Array_Name, Par_Data_Array_Offset, Length
Set_Date, 0,
Set_Date,
Par_Bit_Triggers,
3,
awt,
SYSPLUS_01, Set_Date,
1
This command is used by first writing the parameter data and then triggering the command by writing any value to Data_Array_Name
at Data_Array_Offset.
Parameter data setup:
Offset from par_data_array_offset Description
Month
Day
Year
0
1
2
FS-8700-88 Envirotronics SystemsPlus
Page 33 of 49
4.4.82.
Map Descriptor Example 79 - set time = hour:minute:second
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
Set_Time, Par_Bit_Triggers, 4, awt, SYSPLUS_01, Set_Time,
SysPlus_Cmd, Par_Data_Array_Name, Par_Data_Array_Offset, Length
Set_Time, 0,
1
This command is used by first writing the parameter data and then triggering the command by writing any value to Data_Array_Name
at Data_Array_Offset.
Parameter data setup:
Offset from par_data_array_offset Description
Hour
Minute
Second
0
1
2
4.4.83.
Map Descriptor Example 80 - edit set setpoint channel = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
Ed_Set_Setpoint, Par_Val_Trigger, 0, awt, SYSPLUS_01, Ed_Set_Setpoint, Ed_Set_Setpoint,
SysPlus_Cmd,
Par_Data_Array_Name, Par_Data_Array_Offset, Length
0,
1
This command is used by first writing the parameter data value and then triggering the command by writing channel to
Data_Array_Name at Data_Array_Offset.
Parameter data setup:
Offset from par_data_array_offset Description
Value
0
FS-8700-88 Envirotronics SystemsPlus
Page 34 of 49
4.4.84.
Map Descriptor Example 80 - edit set gsoak channel = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Par_Data_Array_Name, Par_Data_Array_Offset, Length
Ed_Set_Gsoak,
Par_Val_Trigger,
1,
awt,
SYSPLUS_01, Ed_Set_Gsoak, Ed_Set_Gsoak,
0,
1
This command is used by first writing the parameter data value and then triggering the command by writing channel to
Data_Array_Name at Data_Array_Offset.
Parameter data setup:
Offset from par_data_array_offset Description
Value
0
4.4.85.
Map Descriptor Example 81 - edit set gsoak enabled channel = Boolean
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Par_Data_Array_Name, Par_Data_Array_Offset, Length
Ed_Set_Gs_Ena,
Par_Val_Trigger,
2,
awt,
SYSPLUS_01, Ed_Set_Gsoak_Ena, Ed_Set_Gs_Ena,
0,
1
This command is used by first writing the parameter data Boolean and then triggering the command by writing channel to
Data_Array_Name at Data_Array_Offset.
Parameter data setup:
Offset from par_data_array_offset Description
0
Boolean
FS-8700-88 Envirotronics SystemsPlus
Page 35 of 49
4.4.86.
Map Descriptor Example 82 - edit set events = event_list
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Par_Data_Array_Name, Par_Data_Array_Offset, Length
Ed_Set_Events,
Par_Val_Trigger,
3,
awt,
SYSPLUS_01, Ed_Set_Events, Ed_Set_Events, 0, 10
This command is used by first writing the parameter data event_list and then triggering the command by writing the number of events
to Data_Array_Name at Data_Array_Offset.
Note: Only consecutive events can be set ( eg. to set event9, all 10 events must be set and 10 written to Data_Array_Name ).
Parameter data setup: (Use a value of 1 for “on” or a value of 0 for “off” per event)
Offset from par_data_array_offset Description
Event0
..
Event9
0
..
9
4.4.87.
Map Descriptor Example 83 - edit set auxs = aux_list
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd, Par_Data_Array_Name, Par_Data_Array_Offset, Length
Ed_Set_Auxs,
Par_Val_Trigger,
4,
awt,
SYSPLUS_01, Ed_Set_Auxs, Ed_Set_Auxs, 0, 10
This command is used by first writing the parameter data aux_list and then triggering the command by writing the number of auxs to
Data_Array_Name at Data_Array_Offset. Note: Only consecutive auxs can be set ( eg. to set aux1, all auxs from 0 to 1 must be set
and 2 written to Data_Array_Name ).
Parameter data setup: (Use a value of 1 for “on” or a value of 0 for “off” per aux)
Offset from par_data_array_offset Description
Aux0
..
Aux9
0
..
9
FS-8700-88 Envirotronics SystemsPlus
Page 36 of 49
4.4.88.
Map Descriptor Example 84 - edit read program
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Program,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
0,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Program,
Store_Data_Array_Name,
Ed_Rd_Program,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
Program number
0
4.4.89.
Map Descriptor Example 85 - edit read step
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Step,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
1,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Step,
Store_Data_Array_Name,
Ed_Rd_Step,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
Step number
0
4.4.90.
Map Descriptor Example 86 - edit read number steps
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Store_Data_Array_Name, Store_Data_Array_Offset, Length
0,
Ed_Rd_Num_Steps,
Rd_Triggers,
2,
art,
SYSPLUS_01, Ed_Rd_Num_Steps, Ed_Rd_Num_Steps,
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
Number of steps
0
FS-8700-88 Envirotronics SystemsPlus
Page 37 of 49
4.4.91.
Map Descriptor Example 87 - edit read duration
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Duration,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
3,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Duration,
Store_Data_Array_Name,
Ed_Rd_Duration,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
Duration
0
4.4.92.
Map Descriptor Example 88 - edit read events
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Events,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
4,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Events,
Store_Data_Array_Name,
Ed_Rd_Events,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
Event0 status
..
Event9 status
0
..
9
FS-8700-88 Envirotronics SystemsPlus
Page 38 of 49
4.4.93.
Map Descriptor Example 89 - edit read aux.
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd, Store_Data_Array_Name, Store_Data_Array_Offset, Length
Ed_Rd_Aux,
Rd_Triggers,
5,
art,
SYSPLUS_01, Ed_Rd_Aux,
Ed_Rd_Aux,
0,
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
Aux0 status
..
Aux9 status
0
..
9
4.4.94.
Map Descriptor Example 90 - edit read cycles
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Cycles,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
6,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Cycles,
Store_Data_Array_Name,
Ed_Rd_Cycles,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
Number of cycles
0
FS-8700-88 Envirotronics SystemsPlus
Page 39 of 49
4.4.95.
Map Descriptor Example 91 - edit read next
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Next,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
7,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Next,
Store_Data_Array_Name,
Ed_Rd_Next,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
Next
0
4.4.96.
Map Descriptor Example 92 - edit read analog min.
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Ana_Min,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
8,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Ana_Min,
Store_Data_Array_Name,
Ed_Rd_Ana_Min,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
Min analog value
0
4.4.97.
Map Descriptor Example 93 - edit read analog max.
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Ana_Max,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
9,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Ana_Max,
Store_Data_Array_Name,
Ed_Rd_Ana_Max,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
Max analog value
0
FS-8700-88 Envirotronics SystemsPlus
Page 40 of 49
4.4.98.
Map Descriptor Example 94 - edit read analog type
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Ana_Type,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
10,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Ana_Type,
Store_Data_Array_Name,
Ed_Rd_Ana_Type,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Analog type
4.4.99.
Map Descriptor Example 95 - edit read engineering min.
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Eng_Min,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
11,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Eng_Min,
Store_Data_Array_Name,
Ed_Rd_Eng_Min,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Min engineering value
4.4.100.
Map Descriptor Example 96 - edit read engineering max.
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Eng_Max,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
12,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Eng_Max,
Store_Data_Array_Name,
Ed_Rd_Eng_Max,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Max engineering value
FS-8700-88 Envirotronics SystemsPlus
Page 41 of 49
4.4.101.
// Client Side Mao Descriptors
Map Descriptor
Map Descriptor Example 97 - edit read analog address
Map_Descriptor_Name,
Ed_Rd_Ana_Addr,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
13,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Ana_Addr,
Store_Data_Array_Name,
Ed_Rd_Ana_Addr,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Analog address
4.4.102.
Map Descriptor Example 98 - edit read units
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Units,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
14,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Units,
Store_Data_Array_Name,
Ed_Rd_Units,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Units value
4.4.103.
Map Descriptor Example 99 - edit read fuzzy heat cycle time
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Fuz_Hct,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
15,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Fuz_Hct,
Store_Data_Array_Name,
Ed_Rd_Fuz_Hct,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Heat cycle time
FS-8700-88 Envirotronics SystemsPlus
Page 42 of 49
4.4.104.
Map Descriptor Example 100 - edit read fuzzy cool cycle time
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Fuz_Cct,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
16,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Fuz_Cct,
Store_Data_Array_Name,
Ed_Rd_Fuz_Cct,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Cool cycle time
4.4.105.
Map Descriptor Example 101 - edit read fuzzy heat sensitivity
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Store_Data_Array_Name, Store_Data_Array_Offset, Length
0,
Ed_Rd_Fuz_HSens,
Rd_Triggers,
17,
art,
SYSPLUS_01, Ed_Rd_Fuz_HSens, Ed_Rd_Fuz_HSens,
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Heat sensitivity
4.4.106.
Map Descriptor Example 102 - edit read fuzzy cool sensitivity
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Store_Data_Array_Name, Store_Data_Array_Offset, Length
0,
Ed_Rd_Fuz_CSens,
Rd_Triggers,
18,
art,
SYSPLUS_01, Ed_Rd_Fuz_CSens, Ed_Rd_Fuz_CSens,
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Cool sensitivity
FS-8700-88 Envirotronics SystemsPlus
Page 43 of 49
4.4.107.
Map Descriptor Example 103 - edit read fuzzy heat max. power
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Store_Data_Array_Name, Store_Data_Array_Offset, Length
0,
Ed_Rd_Fuz_HMPwr,
Rd_Triggers,
19,
art,
SYSPLUS_01, Ed_Rd_Fuz_HMPwr, Ed_Rd_Fuz_HMPwr,
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Max heat power
4.4.108.
Map Descriptor Example 104 - edit read fuzzy cool max. power
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Store_Data_Array_Name, Store_Data_Array_Offset, Length
0,
Ed_Rd_Fuz_CMPwr,
Rd_Triggers,
20,
art,
SYSPLUS_01, Ed_Rd_Fuz_CMPwr, Ed_Rd_Fuz_CMPwr,
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Max cool power
4.4.109.
Map Descriptor Example 105 - edit read fuzzy heat min. time
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Store_Data_Array_Name, Store_Data_Array_Offset, Length
0,
Ed_Rd_Fuz_HMTim,
Rd_Triggers,
21,
art,
SYSPLUS_01, Ed_Rd_Fuz_HMTim, Ed_Rd_Fuz_HMTim,
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Min heat time
FS-8700-88 Envirotronics SystemsPlus
Page 44 of 49
4.4.110.
Map Descriptor Example 106 - edit read fuzzy cool min. time
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Store_Data_Array_Name, Store_Data_Array_Offset, Length
0,
Ed_Rd_Fuz_CMTim,
Rd_Triggers,
22,
art,
SYSPLUS_01, Ed_Rd_Fuz_CMTim, Ed_Rd_Fuz_CMTim,
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Min cool time
4.4.111.
Map Descriptor Example 107 - edit read fuzzy heat stage delay
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Store_Data_Array_Name, Store_Data_Array_Offset, Length
0,
Ed_Rd_Fuz_HSDly,
Rd_Triggers,
23,
art,
SYSPLUS_01, Ed_Rd_Fuz_HSDly, Ed_Rd_Fuz_HSDly,
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Heat stage delay
4.4.112.
Map Descriptor Example 108 - edit read fuzzy cool stage delay
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Store_Data_Array_Name, Store_Data_Array_Offset, Length
0,
Ed_Rd_Fuz_CSDly,
Rd_Triggers,
24,
art,
SYSPLUS_01, Ed_Rd_Fuz_CSDly, Ed_Rd_Fuz_CSDly,
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Cool stage delay
FS-8700-88 Envirotronics SystemsPlus
Page 45 of 49
4.4.113.
Map Descriptor Example 109 - edit read fuzzy dead band
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Store_Data_Array_Name, Store_Data_Array_Offset, Length
Ed_Rd_Fuz_Deadb,
Rd_Triggers,
25,
art,
SYSPLUS_01, Ed_Rd_Fuz_Deadb, Ed_Rd_Fuz_Deadb,
0,
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Dead band
4.4.114.
Map Descriptor Example 110 - read alarm log
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Rd_Alarm_Log,
Data_Array_Name,
Rd_Triggers,
Data_Array_Offset,
26,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Rd_Alarm_Log,
Store_Data_Array_Name,
Rd_Alarm_Log,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
To be determined !
4.4.115.
Map Descriptor Example 111 - edit read setpoint channel
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Setpoint,
Data_Array_Name,
Rd_Par_Triggers,
Data_Array_Offset,
0,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Setpoint,
Store_Data_Array_Name,
Ed_Rd_Setpoint,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing channel to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Setpoint
FS-8700-88 Envirotronics SystemsPlus
Page 46 of 49
4.4.116.
Map Descriptor Example 112 - edit read gsoak enabled channel
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name,
SysPlus_Cmd,
Store_Data_Array_Name, Store_Data_Array_Offset, Length
Ed_Rd_Gsoak_Ena,
Rd_Par_Triggers,
1,
art,
SYSPLUS_01, Ed_Rd_Gsoak_Ena, Ed_Rd_Gsoak_Ena,
0,
1
This command is triggered by writing channel to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows: ( A value of 1 is used for “true” or 0 for “false” )
Offset from Store_Data_Array_Offset Description
0
Gsoak enabled
4.4.117.
Map Descriptor Example 113 - edit read gsoak channel
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Gsoak,
Data_Array_Name,
Rd_Par_Triggers,
Data_Array_Offset,
2,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Gsoak,
Store_Data_Array_Name,
Ed_Rd_Gsoak,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing channel to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows:
Offset from Store_Data_Array_Offset Description
0
Gsoak value
4.4.118.
Map Descriptor Example 114 - edit read scan alarm
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Rd_Scan_00,
Data_Array_Name,
Scan_Alm_Trigs,
Data_Array_Offset,
0,
Function,
art,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Rd_Scan,
SysPlus_Alarm_Name,
fire,
Store_Data_Array_Name,
Ed_Rd_Scan,
Store_Data_Array_Offset,
0,
Length
1
This command is triggered by writing any value to Data_Array_Name at Data_Array_Offset.
The retrieved data is stored as follows: ( A value of 1 is stored for “Fail” or 0 for “Normal” )
Offset from Store_Data_Array_Offset Description
0
Alarm status
FS-8700-88 Envirotronics SystemsPlus
Page 47 of 49
4.4.119.
Map Descriptor Example 115 - edit set scan alarm = Boolean
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Ed_Set_Scan_00,
Data_Array_Name,
Set_Scan_Trig,
Data_Array_Offset,
0,
Function,
wrbx,
Node_Name,
SYSPLUS_01,
SysPlus_Cmd,
Ed_Set_Scan,
SysPlus_Alarm_Name,
fire,
Length
1
This command is triggered by writing a Boolean value to Data_Array_Name at Data_Array_Offset.
A value of 1 is used for “true” or 0 for “false”.
FS-8700-88 Envirotronics SystemsPlus
Page 48 of 49
Appendix A. Parameter Tables
Appendix A.1. System plus data types
Event
Aux
Setpoint
Pv
Deviation
Init_Setpoint
Selected_Prog
Rem_Step_Tim
Stop_Time_Ena
Audible_Alarm
All_Auxs
Prog_Status
Step_Number
Start_Step
Start_Time
Sw_Version
Alarm
Rem_Step_Cyc
Step_Time
Start_Time_Ena
Stop_Time
All_Events
Appendix A.2. Legal System PlusCommands
Ed_Rd_Program
Ed_Rd_Duration
Ed_Rd_Cycles
Ed_Rd_Ana_Max
Ed_Rd_Eng_Max
Ed_Rd_Fuz_Hct
Ed_Rd_Fuz_CSens
Ed_Rd_Fuz_HMTim
Ed_Rd_Fuz_CSDly
Ed_Rd_Setpoint
Ed_Rd_Scan
Ed_Rd_Step
Ed_Rd_Num_Steps
Ed_Rd_Aux
Ed_Rd_Events
Ed_Rd_Next
Ed_Rd_Ana_Min
Ed_Rd_Eng_Min
Ed_Rd_Units
Ed_Rd_Ana_Type
Ed_Rd_Ana_Addr
Ed_Rd_Fuz_Cct
Ed_Rd_Fuz_HMPwr
Ed_Rd_Fuz_CMTim
Ed_Rd_Fuz_Deadb
Ed_Rd_Gsoak_Ena
Emergency_Stop
Start_Program
Ed_Rd_Fuz_HSens
Ed_Rd_Fuz_CMPwr
Ed_Rd_Fuz_HSDly
Rd_Alarm_Log
Ed_Rd_Gsoak
Hold_Program
Resume_Program
Stop_Program
Start_System
Stop_System
Alarm_Reset
Alarm_Ack
Ed_Alarms
Set_Circs
Set_Lights
Select_Prog
Use_Keypad
Ed_Program
Ed_Step
Ed_Analog
Ed_Fuzzy
Ed_Remove_Step
Ed_Clr_Program
Ed_Set_Next
Ed_Insert_Step
Use_Emu_Mode
Ed_Set_Ana_Min
Ed_Set_Eng_Min
Ed_Set_Units
Ed_Add_Step
Ed_Set_Cycles
Ed_Set_Ana_Max
Ed_Set_Eng_Max
Ed_Set_Fuz_Hct
Ed_Set_Fuz_CSens
Ed_Set_Fuz_HMTim
Ed_Set_Fuz_CSDly
Ed_Set_Duration
Set_Date
Ed_Set_Ana_Type
Ed_Set_Ana_Addr
Ed_Set_Fuz_Cct
Ed_Set_Fuz_HMPwr
Ed_Set_Fuz_CMTim
Ed_Set_Fuz_Deadb
Set_Start_Time
Set_Time
Ed_Set_Fuz_HSens
Ed_Set_Fuz_CMPwr
Ed_Set_Fuz_HSDly
Ed_Set_Scan
Set_Stop_Time
Ed_Set_Setpoint
Ed_Set_Events
Ed_Set_Gsoak
Ed_Set_Auxs
Ed_Set_Gsoak_Ena
End_Edit_Mode
FS-8700-88 Envirotronics SystemsPlus
Page 49 of 49
THIS PAGE INTENTIONALLY LEFT BLANK
|